Search by {{ tax.tax_title }}

{{ filter.name }}

Search by {{ tax.tax_title }}

{{ filter.name }}

No products found

TR-A/V/VMT

Absolute vibration transmitter with 4-20 mA output and DIN rail mounting

Absolute vibration transmitter for PLC and DCS systems.

The TR-A/V/VMT transmitter is designed for absolute vibration measurement of the bearing of any rotating machine by connection to appropriate transducer (accelerometer, velocimeter or velomitor).
Using 2- or 3-wire technology, it provides a 4÷20 mA current or voltage (0-10 V) signal proportional to the measured quantity, allowing direct integration with PLC or DCS acquisition systems. Rugged and compact, it is designed for safe industrial installations, even in classified areas.

Key Features

  • Processes the signal from the transducer and converts it into an analog signal proportional to the measured quantity.

  • It acquires the signal from an accelerometer (TA-18S) or velomitor (TV-22).

  • Converts the dynamic signal to a 4÷20 mA signal for direct interface to PLC/DCS.

  • It has a BNC connector for connecting a handheld instrument (N600, N130, N330) for diagnostics of the monitored machine.

  • It can be installed in safe area and connected via certified barriers to intrinsically safe transducers placed in classified area.

Product complies with European standards

Features

TR-A/V/VMT Main Features

  • Absolute vibration measurement from transducers (accelerometer, velocimeter, velomitor).

  • 4÷20 mA output, compatible with PLC and DCS.

  • 2- or 3-wire technology for wiring flexibility.

  • DIN rail provision for quick installation.

  • BNC connection for vibration analyzers.

  • Dedicated terminal blocks for power supply and signals.

  • Secure connection to transducers certified for classified areas.

Typical applications

  • Vibration monitoring on industrial rotating machinery.

  • Control of electric motors and generators.

  • Protection of compressors, pumps and fans.

  • Supervision of steam and gas turbines.

  • Installations in harsh environments with steam, oil or chemical agents.

  • Integration into PLC/DCS systems for diagnostics and automation.

Technical data

Power supply
  • 24Vdc nominal
  • 2-wire 18-30Vdc version (Maximum load see Figure 1)
  • 3-wire 24-35Vdc version
External connections
  • Terminal block for connection to PLC/DCS (2 or 3 conductor shielded cable, max. cross section 2.5mm²)
  • Terminal block for transducer connection (2-core shielded cable, max. cross section 2.5mm²)
  • BNC for analyzer connection
Environmental scope of use -35°C ÷ +70°C
Type of measurement Absolute vibrations
Dynamic performance 5 ÷ 10,000Hz
Linearity± 2% over the entire measurement range and within the specified operating temperatures
Insulation ≥108 Ω between signals and container